Professional Disinfection Nebulizer
Professional Disinfection Nebulizer

Professional Disinfection Nebulizer

CUBE S – Professional Disinfection NebulizerSmart disinfection. Complete coverage. Safety in any space. Product description CUBE S is a 3D volumetric nebulizer for rapid disinfection...
14.743,00 lei
14.743,00 lei
Please hurry! Only 0 left in stock
Size: S
Packaging: Piece
🚚

Fast delivery in 24–48h

📞

Dedicated support: 021 448 1498 | suport@klintensiv.ro

🧪

Expertise inspired by medical standards

⚙️

Consistent performance in use

🏭

Controlled quality throughout production

🏢

Also available for SEAP/SICAP public procurement

Romanian product • Impeccable quality • Competitive prices • Approved and certified disinfectants

CUBE S – Professional Disinfection Nebulizer
Smart disinfection. Complete coverage. Safety in any space.

Product description

CUBE S is a 3D volumetric nebulizer for rapid disinfection of spaces up to 300 m³ using dry fog, compatible with authorized biocides. It finely distributes the solution and reaches hard-to-access areas without wetting surfaces, making it ideal for homes, offices, clinics/consulting rooms, hotels, retail, and means of transport.

Benefits

  • Uniform coverage of the treated volume, without manual effort or wiping
  • Dry fog – minimal risk of wetting/residue
  • Portable & easy to use – quick setup, automatic shut-off
  • Compatible with most approved biocides (e.g., DESOGEN AERO)
  • High efficiency: treats up to 300 m³ in a few minutes*

*Time depends on room volume, flow rate, and the biocide concentration required.

Technical specifications

  • Max. power: 650 W
  • Nebulized solution flow rate (internal scale): 3 ml/m³
  • Blower pressure: 180 mbar
  • Operating speed: 17,000 rpm
  • Noise level: 105 dB
  • Biocide container volume: 1 L
  • Weight (without container): 6.3 kg
  • Dimensions (L×W×H): 205 × 315 × 252 mm
  • Power supply: 230 V AC

Package contents

CUBE S (1 pc), silicone tube (1), 1 L biocide container (1), power cable (1), user manual (1), leaflet (1), transport protectors (2), self-adhesive nozzle protector (1), “nebulization” door warning sign (1), CUBE Atomizers sticker (1).

Fields of application

Residences, office spaces, medical/dental clinics, hotels, classrooms, commercial spaces/markets, cars, buses, trains, aircraft – anywhere there is an enclosed volume requiring decontamination.

Biocide compatibility

  • Use only biocides approved by the competent authority.
  • The product is compatible with most formulations intended for nebulization (check the biocide’s SDS).
  • Usage example: DESOGEN AERO.

User guide (step-by-step)

  1. Space preparation: calculate the room volume (m³). Restrict access during the treatment.
  2. Installation: fix the biocide container in the holder; connect the silicone tube to the container and the device connector; check for leaks.
  3. Device positioning: place on a horizontal surface, nozzle oriented ~45° upwards; keep a ≥2 m distance from objects.
  4. Volume setting: adjust the volume selector (m³) according to the required dosage (see the “Dosage & settings” section).
  5. Start: switch ON; leave the room immediately. CUBE S shuts off automatically at the end.
  6. After treatment: wait min. 15 min before re-entering, then ventilate.

Dosage & settings (example DESOGEN AERO – 10 ml/m³)

CUBE S has an internal scale of 3 ml/m³. For biocides requiring 10 ml/m³, set the selector using the conversion factor 10/3 ≈ 3.33:

Formula:
Volume displayed on CUBE S = Real room volume
× 3.33

Guidance table (3 ml/m³ scale):

  • Displayed 300 m³ → treats ~90 m³ at 10 ml/m³
  • Displayed 180 m³ → ~55 m³
  • Displayed 150 m³ → ~45 m³
  • Displayed 100 m³ → ~30 m³

Practical example: for a room of 45 m³, set the selector to 150 m³ (45 × 3.33 ≈ 150).

Note: Follow the recommended dosage provided by the biocide manufacturer. If the biocide requires a different dosage (e.g., 5 ml/m³), adjust with the corresponding factor.

Safety & essential precautions

  • DO NOT nebulize harmful, flammable/explosive substances (gasoline, solvents, alcohol, etc.).
  • Evacuate persons from the room during treatment; the operator should only enter with PPE (goggles + full PVC suit) specific to the biocide.
  • Do not start at < 2 m from objects; do not cover the air vents or the nozzle.
  • Do not insert objects/fluids into the nozzle; do not move the device while in operation.
  • Disconnect immediately in case of leaks; remedy the cause.
  • Use only grounded sockets; do not use defective cables/extension cords.
  • Do not open the casing – this voids the warranty.
  • Follow the SDS/MSDS of the biocide used.

Maintenance

  • Wipe the casing with a microfiber cloth; do not spray detergent directly onto the device.
  • When storing, protect the nozzle opening with the self-adhesive protector.
  • Keep the device dry and clean.

Troubleshooting (summary)

  • Does not start: check the power supply, fuse, cable.
  • Starts, but does not spray: check the position/filling of the container, the lid, the nozzle (ensure it is not covered).
  • If the problem persists: service@cubeatomizers.com (do not tamper with the inside).

Standards & compliance

  • 2014/30/EU (EMC), 2014/35/EC (LVD), 2011/65/EC (RoHS).
  • Warranty: 12 months under conditions of use according to the manual.

Warranty

In case of an irreparable defect within 3 hours of verification by an authorized technician, immediate replacement with a new unit (according to the warranty certificate). The warranty is void in case of unauthorized intervention, improper use, faulty power supply, etc.

Contact & support

Questions about biocides & application:
www.klintensiv.ro | office@klintensiv.ro | 021/44.81.498

Recommendation: display the nebulization warning at the entrance to the room during the treatment and observe the waiting/ventilation times indicated by the biocide.

 

Recently viewed products

Frequently Asked Questions

Everything you need to know about our products

A
Nebulizatorul CUBE S este compatibil cu majoritatea biocidelor autorizate de autoritatea competentă. Este important să verificați FDS-ul biocidului utilizat pentru a asigura compatibilitatea.
A
CUBE S poate dezinfecta rapid spații de până la 300 m³. Timpul de dezinfectare depinde de volumul încăperii, debitul și concentrația cerută de biocid.
A
Este esențial să evacuați persoanele din încăpere pe durata tratamentului, să purtați echipament de protecție adecvat (ochelari și echipament PVC integral) și să nu nebulizați substanțe nocive sau inflamabile.